Skip to content
Quote + Documentation

Primary Service

CMM Calibration and Repair

Request a written quotation for calibration or repair.

Request a quotation

A written quotation is sent back by email.

Volumetric Performance, Verified

A CMM that has not been checked since installation, or since a collision, is an unverified measurement source. Calibration against ISO/IEC 17025:2017 establishes whether length measurement error and probing performance still fall inside the machine's stated MPE.

Mechanical faults found during calibration, including scale damage, air bearing wear and probe seating issues, are quoted as repairs before any adjustment proceeds.

What Is Checked

Calibration follows ISO 10360 test procedures appropriate to the machine type, covering length measurement error and probing form error across the working volume.

  • 01

    Bridge and gantry CMMs

    Length measurement error (E0, E150) checked across axes using calibrated gauge blocks or step gauges.

  • 02

    Cantilever CMMs

    Volumetric and probing checks adjusted for the single-support geometry and its error characteristics.

  • 03

    Portable articulated arms

    Single-point articulation and volumetric tests performed with reference artifacts sized to the arm's reach.

  • 04

    Mechanical and controller repair

    Scale, bearing, probe and controller faults diagnosed and quoted separately from the calibration check.

How Requests Are Handled

  • 01

    Scope review

    Make, model and range are checked against the performing laboratory's accredited scope.

  • 02

    Quotation issued

    Calibration and any repair identified in advance from reported symptoms are covered in one written quotation.

  • 03

    Calibration performed

    Testing follows ISO/IEC 17025:2017 with results recorded as-found before any adjustment.

  • 04

    Certificate released

    Reference standards and reported uncertainty are stated on the released certificate.

Why Memphis CMM Calibration and Repair

  • 01

    As-found reporting

    Out-of-tolerance conditions are documented before adjustment, preserving the record for root-cause review.

  • 02

    Repair quoted separately

    Mechanical repairs identified during calibration are quoted on their own, not bundled automatically.

  • 03

    On-site capability

    Fixed bridge and gantry machines are calibrated at the installed location, avoiding disassembly for shipment.

Coverage across West Tennessee and the Mid-South

Service area covers Memphis and surrounding West Tennessee and Mid-South communities. Availability and routing vary by equipment type and location.

Discuss CMM Calibration and Repair Requirements

Describe the machine and the fault, if any.

A written quotation is sent back by email.
Quote + DocumentationEmail us